Digital Equipment Corporation RAID Array 3000 storage subsystem Guia do Utilizador Página 50

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 94
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 49
RAID Array 3000 Pedestal Enclosure
2–22 EK–SMCPO–UG. A01
WARNING
Slow Alarm
Normal I/O
SEVERE
UltraSCSI Alarm
Flushes Cache
Enters Write-Through Mode
OFFLINE
UltraSCSI Alarm
Flushes Cache
No New I/O Allowed
2.9.2 Voltage Monitoring
2.9.2.1 System Voltage
The controller monitors the incoming system voltage levels and ensures they are
satisfactory for controller operation. The acceptable voltage levels are listed in
Table 2–8.
Table 2–8 Acceptable System Voltage Levels
State Range Action
Normal 4.80 - 5.25 V Normal Operation
Low Warning 4.75 - 4.80 V Alarm
High Warning 5.25 - 5.30 V Alarm
Low Severe Less than 4.75 V Off-line
High Severe Greater than 5.30 V Off-line
Vista de página 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 93 94

Comentários a estes Manuais

Sem comentários