RAID Array 3000 Pedestal Enclosure
2–24 EK–SMCPO–UG. A01
2.9.3 Temperature Monitoring
2.9.3.1 External Temperature
The controller monitors the external operating temperature and ensures they are
satisfactory for controller operation. The acceptable temperature levels are
shown in the following table.
Table 2–11 Acceptable External Temperature Voltage Levels
State Temperature Action
Normal < 41º C Normal Operation
High Warning < 41º C - 52º C Alarm
High Severe > 52º C Off-line
2.9.3.2 Board Temperature
The controller monitors the on-board operating temperature and ensures they are
satisfactory for controller operation. The acceptable temperature levels are
shown in the following table.
Table 2–12 Acceptable Board Temperature Voltage Levels
State Temperature Action
Normal < 52º C Normal Operation
High Warning 52º C - 56º C Alarm
High Severe > 56º C Off-line